Stainless Steel Construction See model (D)IBD2SS. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. g. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Ruskin offers threeII-G-Angle-514/Replaces II-IBD Style G -109 ©Ruskin 2014 DYNAMIC FIRE DAMPERS See label on damper for maximum air flow and pressure. 6 psi to 44. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. DIBD2GA fire dampers are idealAMCA Publication 500. The FSDR60 is the ideal choice when round duct is used on a project. The CDO25 is an oval control damper that features: Volume control. 075 lb/cu ft air. Ruskin offers blast suppression dampers which are custom designed to each application. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. It features: AMCA Class 1A leakage for energy savings R value – 2. Dampers shall be in all respects equivalent to Ruskin model CBD6. Sun Control Sunshades. 081" thick extruded aluminum at approximately 4" c-c spacing. would require CD50 damper with maximum section width of 36" (914). Ruskin Fire/Smoke Dampers. 2. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. of 8. FILES (0) Share this page: 1. Rectangular Silencers. • Ruskin frame-mounted actuator bracket to simplify field installation of most actuators (specify actuator and action, i. Specifier Select Options. CDR25 and CDO25 dampers are round and oval volume control dampers. Fire dampers with 11/2 or 3 hour ratings for walls or floors are not to be used in fire rated ceiling openings. 1. The damper shall be rated for dynamic closure at 2000 fpm (10. Specifier Select Option Dampers shall be equipped with factory installed damper. g. For proper operation, damper must be installed square and free from racking. Ruskin fire/smoke dampers. Ruskin Literature. back pressure depending on damper size. Greaves Rd ansas City, O 600 P: 16 761-776 F 16 765-55 E ruskinruskin. Enter the Pressure Drop Chart at the determined area factor. pivot pins. 6) 304tested and classified Ceiling Dampers (also called Ceiling Fire Dampers or Radiation Dampers) to provide fire and heat protection where HVAC components penetrate the ceiling membrane. Use the details shown on pages 2 and 3 to determine how Ruskin multiple blade dampers with standard construction and sizes up to 240" wide by 144" high will be assembled and manufactured. This damper has insulated extruded aluminum blades with a thermal break and twin blade edge seals that ensure low leakage and reliable performance. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Example: Maximum design total pressure of 8. Email. The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERS Catalog. The BD6 backdraft damper is ideally suited to heavy duty applications and is AMCA certified for Leakage and Performance. damper actuators are UL listed for smoke control dampers or for combination fire/smoke rated dampers. These dampers are commonly used for vapor cloud and dust cloud explosions found in petroleum, chemical, defense, government, dust collector,. Refer to the UL approved installation instructions for specific requirements. Zone Control Systems. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. C. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. The damper shall be rated for dynamic closure at 2000 fpm (10. g. Industrial Multi-Blade Control Damper. the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). Pressure Relief Doors. Product• Ruskin FAST Angles • One piece angle shipped with the damper • Available in 1-½" or 2-½" • Metal, wood and masonry walls/floors • Permits damper installation before or after drywall installation • Approved for all Ruskin fire, smoke and fire/smoke dampers LaBOr Saver #2 IntegraL and factOry SLeeveSRuskin® has the largest selections of AMCA certified dampers in the industry. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. 4) steel. 3. The TS150 is an optional device which can be ordered with electric actuators or pneumatic actuators and EP (electro/pneumatic) switches. The switch package shall include two position indication switches linked directly to the damper blade to provide full open and full closed damper. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. • For proper operation, damper must be installed square and free from. 4 psi respectively. 7447 Toll Free: 800. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERSThe FSD60 Combination Fire/Smoke Damper are both UL555 and UL555S Classified, and rated as a 1-1/2 hour fire damper and a Leakage Class I Smoke damper. It: Is standard on all fire/smoke dampers ordered with pneumatic actuators. Link Bar 5. g. 2. Dampers above 40" (1016) – 10 gage with retainer ring. Maximum rating of 2,000 fpm and 4" w. Select from manual cable drive control to fully automated pressure depended and pressure independent. It locks together without bolts, screws, or rivets that could shake loose. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955. When you need to "dial in" branch air flow, Ruskin Model VFBD35 Value Flo "IRIS" Balancing Damper is well suited for ease of installation and labor savings. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. Innovative thermally efficient dampers are fabricated utilizing high yield 6063T6 frame and blade extrusions. Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. For damper styles WR, WC, WO and BC only the duct connection portion extends through the wall and the damper. Consult Ruskin on your Ruskin representative when a damper is to be applied in conditions exceeding recommend-ed maximums. Dynamic fire dampers shall be Ruskin model DFD60-3. Life Safety Dampers. Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. AMCA licensed as a class 1A damper. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. Ruskin furnishes, installs, and factory commissions actuators from a diverse lineup of manufacturers offering 2-position, 3-position, or modulating control. The CD40x2 has an 8" frame and aluminum construction. All calculations are with external mounted actuators and accessories. Damper widths from 12" to 60" (305 to 1524) wide shall not leak any greater than 8 cfm sq. Industrial Multi-Blade Control Damper. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Kansas City, MO 64030 (816) 761 -7476 FAX (816) 765 -8955 L = Diameter + 2 inches (51) "D" Diameter 3. The CFDR2 is a UL555C Classified Round Ceiling Fire Damper. The CDR82 Round Control Damper features: Accurate airflow control within round ductwork systems in medium pressure industrial HVAC systems Desired performance easily attained in pressure differentials of 6"w. Actuator can be field converted to power open and spring or "fail" closed. Concealed linkage out of the airstream for low maintenance and reduced air turbulence. 5 in. D-DIA. II. The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Ruskin Literature. Damper Sleeve Sleeve thickness must be equal to or thicker than the duct con-nected to it. O. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. 5. The foregoing limited warranty does not apply to (i) consumable products and components (e. The Ruskin optional firestopping installation is one of our latest installation instruction supplements we offer. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERS It features: Maximum velocity of 4,000 fpm. Unlike other ceiling. 3. Wood/Steel Stud Wall: #10 screws b. yeoching. , N. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Access Doors. g. effort to avoid misapplication. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. It features: Extruded aluminum construction. Ruskin Literature. 3. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). Commercial Control Damper CD60. 3 sq. com. Torque applied holding damper closed at 10 in. SP100: Dampers shall be equipped with factory installed damper position indication switch package. Ruskin CD30AF1/CD30AF2 con-trol dampers. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. dampers are for use in dynamic (fans on) or static (fans off) sys-tems. Windstops all around. Dynamic fire dampers shall be Ruskin multiple model DFD35. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. MODEL 912 SUGGESTED SPECIFICATION Suggested specification for Model 912 Ruskin Swartwout Fiberglass Series round dampers (revision 6394). 3 (damper installed with duct upstream and downstream). ft and up to . Counter Balanced Backdraft Damper. MODEL CBDR912 FIBERGLASS ROUND BACKDRAFT DAMPER 3900 Dr. It also features: Frame corners that are internally braced to reduce racking. Ruskin Literature. a. 3. (2 kPa). L501) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood Factory or field supplied plenums Assembly designed to accept grilles with up to ¾” (19) grille depth Through. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. per sq. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. The results show that Ruskin’s CBS8BL dramatically reduces the blast impulse thus protec Ruskin blast damper charts below highlight results of independent third party lab testing of model CBS8BL to peak reflective pre B Impl ( ows ra m Ope nDu ct) Blast Impulse (Downstream Damper)of damper with minimum of 20 in. com W: Ruskin® manufactures an extensive line of UL-rated and listed dampers to protect your life and property. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec - ommended maximums. The TDP05K is capable of measuring a velocity range from Oto 5,000 FPM and displaying the flow and temperature. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. 3. It is rated as a 1-1/2 hour fire damper and a Leakage Class II Smoke damper. specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. The SD60M is a UL555S Classified Leakage Class I modulating smoke damper. Replacement Electronic Heat Sensors and Pneumatic Fuse Links for Combination Fire Smoke Dampers. g. Ceiling fire dampers, also known as "Radiation" dampers, are designed and tested to limit the radiant heat transfer through an air inlet/outlet opening in the ceiling membrane of a fire resistance rated floor/ceiling or. | Ruskin. Dampers shall be in all respects equivalent to Ruskin model CBD2. Various relief air control settings are created by simple. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. . Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance This catalog offers Damper customers an easy to use buying guide for miscellaneous Ruskin Damper parts. Quick Select. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Inspiring the industry with thought provoking, revolutionary ideas, Ruskin airfoil blade dampers comprise the only damper design incorporating a single piece roll-formed frame and blade. UL approval for dual directional air flow. • Airfoil blade design for low pressure drop and reduced noise generation. dampers. When joining multiple damper assemblies or fastening the damper to the sleeve, dampers shall be fastened with 1/4-20 (M6) bolts, number 10 (M5) screws, or 1/2" (13) long welds stag-gered intermittently on both sides. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. 1. Do not weld or fasten angles together at cor-ners of dampers. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. With the variety of models, sizes, and paint finishes available, Ruskin Louvers can add unusual and appealing features to exterior and interior elevation. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). The CD80AF2 Industrial Control damper has an 8" frame. 2 and can be equipped with factory-mounted actuators. Galvanized Steel V-Groove Blades. 248 Kpa) tested per AMCA 500. angles together at corners of dampers. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. While is it true that triple V blade dampers and modified single skin type have been qual-ified to 3000 - 4000 fpm or more at 4" w. A change anywhere is a change everywhere, instantly!2. g. 2. Louver blades are . Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. g. It features a galvanized steel frame, single skin blades, and a variety of actuator options. g. Galvanized Steel Airfoil Blades. For some applications, it is essential that thermal conductivity be kept at a minimum. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. See “Combination Fire Smoke Damper Multiple Section Detail” spec Ruskin February 222 Page 1 FDR25SS Stainless Steel True Round Fire Damper 1 1/2 Hour UL555 Ratings for use in Dynamic & Static Systems Ruskin FDR25SS is a stainless steel true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. 75" w. 4 inches w. Face and by-pass arrangement. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. • Fire smoke dampers larger than single section may require multiple actuators. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. Their line includes duct smoke detectors, flanged breakaway connections, fire damper angles, auxiliary switches, and more. Damper shall be Ruskin model BTR82. The CBDR82 damper blade willRuskin is pleased to announce the availability of Revit® 3-D files of select products. of damper with minimum of 20 in. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. As a Corridor Damper it is designed to be used in openings in the ceilings ofRuskin anuary 2021 Page 2 1. So turn “on” to energy savings while your building is“off” and let Ruskin start saving you money today. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. 5hr Static Fire Dampers » 3hr Static. Axles that positively lock to blades without screws or welds. Enter your email and join our mailing listDesigned for isolation and containment of the airstream, Ruskin bubble tight industrial dampers for round or rectangular air paths will meet or exceed bubble tight leakage requirements in conformance with AMCA Standard 500D and are available with factory-supplied and mounted actuation. Multi-section dampers typically use jackshafts to link sections together. of damper with minimum of 20 in. Refer to the UL approved installation instructions for specific requirements. 761. Dimensions shown in parentheses ( ) indicate millimeters. Mounting Angle FastenersCurtain Type Static Fire Dampers 3 Hour Ul555 Rated For Use In Static Systems Ruskin Model IBD23 is a 3 hour UL classified static (fans off) curtain style fire damper for use in HVAC systems that shut down during a fire event. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. G. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. 2) wall thickness with 12 gage (2. All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. 761. • Fire smoke dampers larger than single section may require multiple actuators. COMMERCIAL CONTROL, MANUAL, AND. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. The Damper part prices in this catalog do include freight within the contiguous 48 states. It features: Vertical blades. lbs. Ruskin manufactures an extensive line of UL rated and listed dampers to protect life and mitigate property loss during a life safety event. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. GENERAL INSTALLATION NOTES 1. 3900 Dr. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. Industrial FAQs. Commercial Control Dampers; Sound Control; Industrial Control Dampers; Software. Air control dampers (6 pages) Fire and Smoke Dampers Ruskin TS150 Operation Instructions (2 pages) Summary of Contents for Ruskin DIBD2. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. Noise Control. FSD36 126"x 96"or 72"x 122" 4"w. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. It features: 1-1/2 hour rating. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. Ruskin "pressure relief" style purge dampers are designed specifically to provide additional make-up air to incineration sys-tems prior to fan start-up. Maximum Damper Width (A Dimension) Maximum Damper Width (A Dimension) AREA FACTOR TABLE EXAMPLE: 1. A. Masonry/Wall or Floor: #10 self-tapping concrete screws. Pressure Relief Doors. Aluminum construction. g. (2) 1/4-20 Nuts 2. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. upstream of the damper. Standard, 1 1/2 and 3 hr. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. These combination fire and smoke dampers are designed for installation with the blades running horizontally. When Ruskin’s Fire/Smoke Dampers are supplied with a factory installed damper sleeve, the sealed. Learn how to select the best damper for your system and achieve optimal air. > Case Studies. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. The CFDR5 is a Round, UL555C Classified Ceiling Fire Damper. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowdamper that can be used as supply/return air plenum to connect to AHU unit below the ceiling assembly. g. Specifying and installing low-leakage dampers (Class 1 preferred, Class 2 at a minimum by code) helps ensure that the building HVAC system is operating at its most energy-efficient level. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Damper shall be Ruskin model CDRS82. g. The EFL is standard on all fire/ smoke dampers ordered with electric actuators. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Get free shipping on orders over $999!%PDF-1. static pressure. Products include differential pressure probes for high velocity applications, combination units that measure and maintain flow, and highly sophisticated, intelligent solutions that incorporate thermal dispersion technology with microprocessor based. A. Standard damper assemblies are furnished ¼” smaller. per sq. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. g. Frame shall be 16 ga. Ruskin UL listed solutions are available. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. 2 m/s) and 4” w. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance. lbs. 3 m/s) and 8” w. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40, CDRS15, CDRS25, TED40 and TED50. Blades have an integral structural reinforcing tube running full length of each blade. Ruskin Literature. For the name and address of your Ruskin Representative, call (816) 761-7476, or visit our web site at Ruskin can engineer and install pneumatic, electric or manual type actuation to best meet your specifications. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. We are the leading manufacturer of air. /Class III, V-Groove Blade,. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD50-CE. Rep Login (817) 509-2300 [email protected] you are looking for a thermally efficient damper that can reduce energy costs and prevent condensation problems, you may want to check out the Ruskin model TED50. It features: Maximum velocity of 4,000 fpm. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Ruskin backdraft damper model CBDR82 is designed to open under flow and to prevent back-flow in industrial HVAC or process control systems. cealed in the frame. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. 25" w. Ruskin Brands and Locations. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. The webpage provides the specifications and features of the Ruskin® CD80AF1 and CD80AF2 industrial control dampers, which are designed for heavy duty applications and high temperature environments. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. It features: For use in static systems Galvanized steel construction. Call (847) 773-0645. INSTALLATION For proper operation, damper must be installed square and free from racking. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. w/ damper - - ELF6375DXD Horizontal drainable blade Wind-borne debris regions (non-essential buildings), HVHZ, areas with rain management system ±148 6” N/A TDI Water, Air 540 & 550 w/ damper ELC6375DXD Horizontal drainable combination louver/ damper Hurricane-prone regions, HVHZ, areas with rain management system, applications. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. M. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. 24VAC modulating actuators (spring return or fail-in-place) can. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. Shims should be used between damper frame and opening or duct to. of damper with minimum of 20 in.